Water purification information

Do you know what common instruments/meters are needed for reverse osmosis systems?

Views : 14254
Author : Susan
Update time : 2024-09-29 16:27:17
Do you know what common meters are needed for reverse osmosis systems?Today Susan to answer some questions for you about water treatment equipment, I hope to be able to help you.
In order to make the RO device can be safe and reliable operation, easy to monitor the operation process, should be equipped with the necessary instrumentation and control devices, generally need to install the instrumentation has a temperature meter, flow meter, pressure meter, conductivity meter, oxidation potential meter, chlorine meter, pH meter, specific as follows:

1. temperature meter:
Feed water temperature meter, because the water production is related to the temperature, so it needs to be tested in order to find out the standardized water production, large-scale equipment should be recorded, in addition, the temperature exceeds 45 ℃ will damage the membrane element, so the raw water heater system should be set up to exceed the limit of the alarm, over the limit of the automatic drainage and shutdown RO protection.

2. Pressure gauge:
The feed water pressure gauge, the first section RO effluent pressure gauge, and the drain pressure gauge are used to calculate the pressure drop in each section and to standardize the water production and salt transmission rate. Salt transmission rate, water yield and Δp are used to analyze RO performance problems.
The 5um filter should be installed with inlet and outlet pressure gauges, and when the pressure drop reaches a certain value, the filter element needs to be replaced.
Inlet and outlet pressure gauges for feed pumps, inlet and outlet pressure switches are used to shut down the pump when the inlet pressure is low and to stop the pump when the outlet pressure is high.

3. flow meter:
Product water flow meter in operation to detect the amount of water produced, each section should be installed separately, in order to standardize RO performance data.
Product water flow rate should be indicated, totalized and recorded. Concentrated water drainage flow meter detects drainage during operation and shall be indicated cumulative and recorded. From the product flow rate and drainage flow rate can be calculated from the sections of the water supply, recovery rate and the recovery rate of the entire RO, feed water flow meter is mainly used for RO dosage of automatic adjustment, in addition to indicating the cumulative signal should also be given for proportional adjustment.

4. conductivity meter:
Feed water conductivity meter, water conductivity meter indicates and records the conductivity of water: alarms can be set, and the desalination rate can be calculated from the conductivity of feed water and the conductivity of produced water.

5. pH meter
When acid is added to the feed water to prevent CaCO3 from forming scale, a pH meter should be installed in the feed water after acid is added.

6. chlorine meter
Chlorine meter is installed in the feed water to control the chlorine content of the feed water.

7. Oxidation potential meter
By adding sodium bisulfite to eliminate chlorine residual feed water should be equipped with redox point meter, there should be an indication of the record, exceed the limit alarm.

The above is the general knowledge of water treatment equipment, I hope you can help you, if you want to know more about the general knowledge of water treatment, welcome to leave a message in the comments section, I will try to reply, if you want to watch more water treatment knowledge please contact me through the following business card. Thank you for reading and have a nice life!


 
Related News
Read More >>
Do water purifiers actually work? Does it work? Does it work? Do water purifiers actually work? Does it work? Does it work?
Oct .23.2024
Is a water purifier actually useful? Is it useful? Is it useful? Let me tell you, useful to burst!
Professionals also say that in our current drinking water environment, water purifier is a little hero:
Characteristics of Reverse Osmosis Membrane Heavy Contamination and Offline Cleaning? Characteristics of Reverse Osmosis Membrane Heavy Contamination and Offline Cleaning?
Oct .23.2024
Reverse osmosis system design will have a certain degree of surplus, to ensure that in the emergency time is not because of the reverse osmosis system of water production or desalination rate drop, reverse osmosis system differential pressure rise and make the water supply is not enough to cause a threat to the safety of the production, but in fact it is also because of the existence of these surplus makes the hidden faults are sometimes not able to show in time, so that ultimately may be evolved into reverse osmosis membrane Heavy contamination of reverse osmosis membrane elements.
Water Purifier VS Tap Water VS Bottle Water: Which is the safest choice for your home? Water Purifier VS Tap Water VS Bottle Water: Which is the safest choice for your home?
Oct .22.2024
Introduction: When we talk about health, we can't help but think about the happiness of the rich and the wealth of the poor. Health is not only the key to live a long life, but also the key to live a quality life. However, in our pursuit of quality of life at the same time, drinking water safety issues gradually become the biggest threat to our health. Is it worthwhile to pay for water purification equipment, and is water purifier really useful? Let's analyse this controversial topic in modern life.
Think water purifiers are expensive? Installing a water purifier saves you more money than you think!!!! Think water purifiers are expensive? Installing a water purifier saves you more money than you think!!!!
Oct .21.2024
Do you have a water purifier in your house? Have you been struggling with whether to install it or not? It's not because we think it's too expensive, but we're worried that it's not worth the investment, or we're afraid of being fooled. Let's talk about this topic today and see if it's worth installing one at home or not.